Assessment of HER-2/neu status in breast cancer. Automated Cellular Imaging System (ACIS)-assisted quantitation of immunohistochemical assay achieves high accuracy in comparison with fluorescence in situ hybridization assay as the standard.

TitleAssessment of HER-2/neu status in breast cancer. Automated Cellular Imaging System (ACIS)-assisted quantitation of immunohistochemical assay achieves high accuracy in comparison with fluorescence in situ hybridization assay as the standard.
Publication TypeJournal Article
Year of Publication2001
AuthorsWang S, Saboorian MH, Frenkel EP, Haley BB, Siddiqui MT, Gokaslan S, Wians FH, Hynan L, Ashfaq R
JournalAm J Clin Pathol
Volume116
Issue4
Pagination495-503
Date Published2001 Oct
ISSN0002-9173
KeywordsBreast Neoplasms, Gene Amplification, Gene Expression, Humans, Image Processing, Computer-Assisted, Immunohistochemistry, In Situ Hybridization, Fluorescence, Receptor, ErbB-2, Retrospective Studies, ROC Curve, Sensitivity and Specificity
Abstract

This retrospective study of formalin-fixed infiltrating breast cancer specimens compared manual immunohistochemical assay with a new image analyzer-assisted immunohistochemical quantitation method, using fluorescence in situ hybridization assay (FISH) as the standard. Following the manual immunohistochemical assay, 189 cases, including most manual immunohistochemically positive and some random negative cases, were analyzed by FISH assay for Her-2/neu gene amplification and by the Automated Cellular Imaging System (ACIS) for immunohistochemical staining. Using the FISH standard, the ACIS immunohistochemical assay attained a higher concordance rate and sensitivity than the manual immunohistochemical assay (91.0% and 88% vs 85.7% and 71%, respectively), with only a slight decrease in specificity (93% vs 96%, respectively). In particular, the ACIS immunohistochemical assay resulted in a higher correlation with the FISH assay in the manual immunohistochemical assay 2+ cases. The ACIS immunohistochemical assay achieved higher accuracy than the manual method according to receiver operating characteristic curve analysis. The ACIS method represents a substantial improvement over the manual method for objective evaluation of the HER-2/neu status.

DOI10.1309/TMUW-G4WB-LXJ2-FUDN
Alternate JournalAm J Clin Pathol
PubMed ID11601134
Related Faculty: 
Momin Siddiqui, M.D.

Pathology & Laboratory Medicine 1300 York Avenue New York, NY 10065 Phone: (212) 746-6464
Surgical Pathology: (212) 746-2700